Scintillation sensitivity in a 90 g instrument you run with one button: dose rate, accumulated dose, alarms and a built-in Food Check.

2,000–3,000 CPM/µSv/h (Cs-137): many times the counts of a typical GM tube, so readings settle faster and low levels become visible.
128 × 240 backlit LCD with a 2-minute trend graph, statistical uncertainty (±%) and Korean or English screens.
Short press to move between menus, long press to act. Alarm level, averaging time and sound are set on the device.
IP64, 1 m drop, about 3 days per charge with auto backlight and USB charging.
QSF104, QSF104B and QSF104F calculate the detection limit and the Food Check result themselves, at 95% confidence (2σ). No manual count logging or calculation needed.




Gamma and X-ray detector with built-in Food Check.
View details →
Adds beta detection for surface contamination checks.
View details →
Highest sensitivity in the series for food screening.
View details →
Entry model with beta, gamma and X-ray detection.
View details →| QSF104 | QSF104B | QSF104F | QSF104m | |
|---|---|---|---|---|
| Radiation | Gamma, X-ray | Beta, gamma, X-ray | Beta, gamma, X-ray | Beta, gamma, X-ray |
| Energy range | 50 keV – 6 MeV | 10 keV – 6 MeV | 10 keV – 6 MeV | 100 keV – 6 MeV |
| Gamma sensitivityCs-137 | ≥ 2,000 CPM/µSv/h | ≥ 2,000 CPM/µSv/h | ≥ 3,000 CPM/µSv/h | ≥ 800 CPM/µSv/h |
| Beta sensitivitySr-90 0.1 µCi at 1 cm | – | 6,000 CPM | 8,000 CPM | 2,000 CPM |
| Food Check (Bq/kg) | O | O | O | X |
| Menus | 9 | 9 | 9 | 8 |
| Sensor | CsI(Tl) scintillator + photodiode, 1.5 mm aluminum EMI shield |
|---|---|
| Dose rate / accumulated dose | 0.001 – 100 µSv/h / 0.001 µSv – 999.9 mSv |
| Total count / count rate | 0 – 999 M counts / 0 – 99,999 CPM |
| Accuracy | 15% or 0.05 µSv/h (Cs-137) |
| Display | Monochrome 128 × 240 dots, backlight, Korean / English (firmware option) |
| Alarm | 2-color LED (green / red), magnetic buzzer ≥ 60 dB |
| Battery | Li-polymer 3.7 V 1,200 mAh, USB 5 V charging; about 6 h (backlight on) / 3 days (auto off) |
| Size · weight | 95 × 60 × 17 mm, 90 g; ABS body with aluminum front plate |
| Environment | −10 – 50 °C, 20–90% RH (non-condensing), IP64, 1 m drop |
| In the box | Detector, USB charger and cable, user manual |
Dedicated container the Food Check is calibrated for. Required for Bq/kg results.
Cuts the natural background to one-fifth or less and lowers the detection limit well below 100 Bq/kg.
100 Bq/kg reference solution to check the sensitivity constant yourself.
Grip and drop protection for daily field use.
Data output with collection software for logging on a PC.
In-house calibration report or KOLAS-accredited calibration on request.
Tell us the model, quantity and destination country. We will reply by email.